PVC Insulated Power Cabl
Product Standard
The product, manufactured according to national standard GB/T12706.1-2002 or International Electrotechnical Commission Standard LEC 502-199, is applicable to transmission and distribution lines with an AC rated voltage (uo/u) of 0.6/1kv and below.
Flame-retardant cables are manufactured according to company standard, with flame-retardant performance in accordance with the requirement of national standard GB12666.5.
Flame-resistant cables, which are manufactured according to company standard, are in accordance with the requirement of national standard GB1266.6 in terms of flame-resistant performance, and ided into A and B flame-resistant types (950-1,000℃/90min, 750-800 ℃/90min) according to national standard GB12666.6.
Low-smoke low-halogen flame-retardant cables are manufactured according to company standard, with the flame-retardant performance in accordance with the requirement of national standard GB 1266.5, and light transmittance of no less than 35 percent, and hydrogen chloride release of no more than 100mg/g.

Product Model, Name, Application Range
Model Name Application Range
VV Copper-cored PVC Insulated and PVC Sheathed Power Cable laid indoors, in tunnels and pipelines, the cable cannot endure external mechanical force, and single-cored cable is not allowed to be laid in magnetic material pipelines
VV22 copper-cored PVC insulation steel tape armored and copper-cored PVC sheathed cable laid indoors, in tunnels, pipelines and underground, the cable can endure external mechanical force, but cannot endure large tensile force. Single-cored cable is not allowed to be laid in magnetic material pipelines.
Note:
1) ZR-is added before the number of common flame-retardant cables; the flame-retardant cables are characterized by difficult combustion or second combustion in a certain range when combusting, and application to occasions with higher intensity of cables, such as power plant, metro, tunnel, high-rise building, large industrial and mining enterprises, oil fields and coal mines.
2) NH- is added before the number of common flame-resistant cables; the flame-resistant cables are characterized by power transmission under normal working condition, normal operation in certain time when combusting, and application to occasions related to fire-proof safety and fire-fighting and lifesaving, such as nuclear power plant, metro and high-rise building.
3) DDZ- is added before the number of common low-smoke low-halogen flame-retardant cables; the low-smoke low-halogen flame-retardant cables are characterized by flame-retardant performance, lower smokiness, low hydrogen chloride release amount, and wide application to occasions with certain requirement on smoke concentration of cable combustion, and release amount of hydrogen chloride gas.

Product Specification
Cable Model Core Number Nominal Cross Sectional Area
(m㎡)
Cable Model Core Number Nominal Cross Sectional Area
(m㎡)
V VV V22 1 1.5~63010~400 V VV V22  1.5~185 4~185
V VV V22 3 1.5~300 4 ~300 V VV V22  3+1 4~300 4~300 
V VV V22 3+2 4~300 4~300 V VV V22  4~300 4~300 
V VV V22 4+1 4~3004~300 V VV V22  5 4~300 4~300


Cable Chart


Product Service Characteristics
1. Highest rated temperature
when the cables are used for long term, the highest working temperature of the cable conductor is 70℃; when in short circuit (the longest sustaining time does not exceed 5 seconds), the highest temperature of cable conductor does not exceed 60℃.
2. Installation Requirement
During laying, the environmental temperature is not lower than 0℃ and the allowed minimum bend radius is: single-cored cable 15 (D+d), and multi-cored cable 50 (D+d) (D is outer diameter of cables, d is diameter of main conductor). Product specification.

Product Parameter
VV22   ZR-VV22  NH-VV22   0.6/1KV
 

Core Number*Nominal Cross Sectional Area(mm2) Approximate Outer Diameter(mm) Allowed Current-carrying Capacity of Copper-cored Cable under 25℃(A) Approximate Weight of Finished Product(kg/km)
Air Laying Underground Laying
10 13.0 70 80 314
16 14.0 93 102 389
25 15.7 118 131 527
35 16.9 147 156 648
50 18.7 176 191 813
70 20.5 224 233 1050
95 22.7 275 279 1371
120 24.4 319 319 1638
150 26.4 368 359 1959
185 28.7 425 409 2394
240 31.9 504 475 3333
300 36.2 579 540 4091
400 39.7 685 620 4972
2×4 16.3 34 41 388
2×6 17.3 43 53 454
2×10 20.0 58 70 589
2×16 22.0 77 92 748
2×25 25.5 104 122 1029
2×35 27.8 129 149 1276
2×50 26.5 146 171 1487
2×70 30.3 188 214 2178
2×95 34.2 27 267 2800
2×120 36.5 274 306 3365
2×150 40.0 316 346 4059
2×185 43.8 368 394 4984
3×4 17.0 29 36 450
3×6 18.1 37 45 538
3×10 20.8 50 60 745
3×16 32.1 66 79 983
3×25 26.9 90 105 1344
3×35 29.3 111 127 1702
3×50 31.2 129 148 2344
3×70 34.4 165 185 3017
3×95 38.6 206 221 3913
3×120 41.7 242 261 4741
3×150 45.5 281 296 5790
3×185 51.0 328 337 7013
3×240 57.3 386 389 8930
3×300 61.5 445 441 11350
3×4+1×2.5 17.6 30 37 495
3×6+1×4 19.1 38 46 608
3×10+1×6 21.8 52 64 834
3×16+1×10 25.5 70 84 1143
3×25+1×16 28.2 93 108 1607
3×35+1×16 30.5 113 130 2060
3×50+1×25 37.0 142 158 2795
3×70+1×35 40.7 181 198 3581
3×95+1×50 45.0 222 236 4676
3×120+1×70 49.7 258 269 5751
3×150+1×70 52.0 297 303 6788
3×185+1×95 59.5 338 340 8371
3×240+1×120 69.5 404 396 10523
3×300+1×150 70.0 472 450 13572
3×4+2×2.5 18.5 30 37 543
3×6+2×4 20.2 38 47 686
3×10+2×6 22.9 53 64 935
3×16+2×10 26.0 71 84 1296
3×25+2×16 30.2 94 107 1880
3×35+2×16 33.5 116 129 2554
3×50+2×25 38.8 141 154 3396
3×70+2×35 43.6 182 193 4447
3×95+2×50 49.4 222 229 5848
3×120+2×70 55.0 256 261 7349
3×150+2×70 59.1 291 291 8454
3×185+2×95 65.6 337 331 10568
3×240+2×120 73.7 401 385 13362
3×300+2×150 81.5 462 439 16419
4×4 18.2 30 37 529
4×6 19.3 38 46 641
4×10 22.5 53 64 905
4×16 25.0 71 83 1218
4×25 29.2 94 108 1690
4×35 33.5 117 132 2479
4×50 34.3 140 157 2963